Agreseal aggregate sealer is a deep penetrating, solvent-based acrylic sealer that provides a glossy, wet look to the aggregate. Agreseal is recommended as a two-coat system with a durable surface ideal for pedestrian and light vehicle traffic. Agreseal repels water and enhances the colour of aggregates and concrete, while protecting the surface against most stains, such as grease and oil.
| Packaging: | 20L |
|---|---|
| Appearance: | Clear colourless viscous liquid |
| Solubility: | PaveCoat Thinners |
| Film Forming Temperature: | 8°C |
| Coats Required: | 2 Coats |
| Recoat Time: | 1 Hour |
| Touch Dry: | 30 Minutes |
| Full Cure: | 7 Days |
| VOC Levels: | 80% |
| Flammability: | Highly (80% Volatiles) |
| Gloss Levels: | High Gloss |
| Ambient Application Temperature: | 8°C – 30°C |
| Coverage Rate: | 3 – 5 m2/L |
Etch the uncoated surface with EcoSafe Etch or EcoSafe Ultra Etch, as outlined in the relevant TDS.
Observe ambient application Conditions noted in the TDS.
Ensure that the surface is clean and dry.
If the surface is affected by white efflorescence, broom over with clean PaveCoat Thinners to dissolve and dissipate all salts before sealing.
Stir thoroughly before use.
1st Coat: Dilute Agreseal up to 50% PaveCoat Thinners
Apply one even coat using a soft bristle broom, roller or spray at the rate of 3 – 5m2/L.
Note: Avoid ponding or pooling. Light mist spray or roller application techniques will not ensure adequate surface penetration or long-term coating performance.
2nd Coat: Apply without solvent dilution in the same manner as the first coat.
If an inadequate seal thickness is applied on newly exposed aggregate, some efflorescence (salt whitening) may occur. This white powder can usually be washed off easily and should cease after several months.
The application of one or two additional coats of Agreseal can prevent the appearance of efflorescence or white salts.
Before commencement, determine whether the existing Aggregate has been previously sealed. To determine an existing coating, refer to the Nutech Coating Test Kit for detailed instructions or contact Nutech Paint.
Very old, incompatible, delaminating problem sealers:
This surface will require reactivation to improve inter-coat adhesion between compatible sealers.
Before reactivation, the exposed aggregate surface should be free from lichen, moss, oil and other debris.
Refer to the EcoSafe Moss Rid and/or EcoSafe Degreaser TDS for further recommendations.
NOTE: To reactivate an existing compatible sealer, using Reactivating Solvent will help improve adhesion to the existing sealer.
A test patch should be performed and assessed before sealing the area. Should the test patch fail, removal of the old sealer, acid etching, and high-pressure water cleaning will be required before applying Agreseal.
Thoroughly clean using EcoSafe Degreaser. Refer to the relevant TDS for further recommendations.
Etch an uncoated surface with EcoSafe Etch or EcoSafe Ultra Etch as outlined in the relevant TDS.
Apply one even coat using a soft-bristled broom, roller, or spray at a rate of 3–5 m²/L.
Note: Avoid ponding or pooling. Light mist spray or roller application techniques will not ensure adequate surface penetration or long-term coating performance.
2nd Coat: Apply without solvent dilution in the same manner as the first coat.
The information in this data sheet is based on extensive experience and is accurate to the best of our knowledge. However, as the use of our product is beyond our control, we can only be responsible for the quality of our product at the time of dispatch. For additional information about specifications or applications, please contact our company. As this information is general, we cannot assume responsibility for individual use.
EcoSafe Etch is designed for mature concrete and provides a suitable finish prior to sealing…
View productsPaveCoat is a high performance, solvent-based acrylic penetrating sealer that provides excellent durability in clear…
View products